Electrosurgical Unit for Hospital, Distributor and Contractor Projects
Huifeng Medical, established in 1992 in Shanghai, manufactures electrosurgical units under the SHANGYI and HFMED brands for hospitals, distributors and contractors. This page covers bipolar, high frequency, monopolar and diathermy models supplied for project orders.
Request a quote for this equipment
- Established
- 1992
- Production lines
- More than 10
- Sales
- More than 50 countries

Electrosurgical Unit Overview
An electrosurgical unit is operating-room equipment that delivers current through electrodes during surgery. Project scope, quantity and destination are handled when you request a quotation for your project.
The page covers the Bipolar Electrosurgical Unit, the High Frequency Electrosurgical Unit, the Monopolar Electrosurgical Unit, the Electrosurgical Unit Diathermy Machine, the Electrosurgical Diathermy Machine, the Electrosurgical Unit Monopolar Bipolar and the Electro Surgical Unit. Output modes, output ratings and physical details stated in a model’s table apply to that model only. Huifeng Medical was established in 1992, became a joint-stock company in 2018 and manufactures under the SHANGYI and HFMED brands.

Benchtop generator with CUT and COAG displays 
Generator atop wheeled cabinet with two drawers
Electrosurgical unit models and specifications
| Parameter | Value |
|---|---|
| Technical Parameters | HF-350C |
| Relative Humidity Range | ≤80 |
| Power | 220V±22v, 50Hz±1 |
| Operating Freq | 330-460kHz |
| Rated power | 1100 VA±10% |
| Type | CF |
| Power Consumption | ≤1100 VA (Cut function 400) |
| b) Relative Humidity | ≤95% |
| c) Atmospheric Pressure | 500hpa-1060 hpa |
| Power output | 400W |
| Six output mode | 1. Cut; 2. Blend 1; 3. Blend 2; 4. Electro Coag 1; 5. Electro Coag 2; 6. Bipolar Coagulation. |
| Output Rating | |
| a) Cut | 1W-400W (Load 500Ω) |
| b) Blend 1 | 1W-200W (Load 500Ω) |
| c) Blend 2 | 1W-120W (Load 500Ω) |
| d) Electro Coag 1 | 1W-150W (Load 500Ω) |
| e) Electro Coag 2 | 1W-80W (Load 500Ω) |
| f) Bipolar Coagulation | 1W-70W (Load 500Ω) |
| Parameter | Value |
|---|---|
| Technical Parameters | HF-350A |
| Relative Humidity Range | ≤80 |
| Power | 220V±22v, 50Hz±1 |
| Operating Freq | 330-460kHz |
| Rated power | 1100 VA±10% |
| Type | CF |
| Power Consumption | ≤1100 VA (Cut function 400) |
| b) Relative Humidity | ≤95% |
| c) Atmospheric Pressure | 500hpa-1060 hpa |
| Power output | 400W |
| Six output mode | 1. Cut; 2. Blend 1; 3. Blend 2; 4. Electro Coag 1; 5. Electro Coag 2; 6. Bipolar Coagulation. |
| Output Rating | |
| a) Cut | 1W-400W (Load 500Ω) |
| b) Blend 1 | 1W-200W (Load 500Ω) |
| c) Blend 2 | 1W-120W (Load 500Ω) |
| d) Electro Coag 1 | 1W-150W (Load 500Ω) |
| e) Electro Coag 2 | 1W-80W (Load 500Ω) |
| f) Bipolar Coagulation | 1W-70W (Load 500Ω) |
| Parameter | Value |
|---|---|
| Technical Parameters | HF-350B |
| Relative Humidity Range | ≤80 |
| Power | 220V±22v, 50Hz±1 |
| Operating Freq | 330-460kHz |
| Rated power | 1100 VA±10% |
| Type | CF |
| Power Consumption | ≤1100 VA (Cut function 400) |
| b) Relative Humidity | ≤95% |
| c) Atmospheric Pressure | 500hpa-1060 hpa |
| Power output | 400W |
| Six output mode | 1. Cut; 2. Blend 1; 3. Blend 2; 4. Electro Coag 1; 5. Electro Coag 2; 6. Bipolar Coagulation. |
| Output Rating | |
| a) Cut | 1W-400W (Load 500Ω) |
| b) Blend 1 | 1W-200W (Load 500Ω) |
| c) Blend 2 | 1W-120W (Load 500Ω) |
| d) Electro Coag 1 | 1W-150W (Load 500Ω) |
| e) Electro Coag 2 | 1W-80W (Load 500Ω) |
| f) Bipolar Coagulation | 1W-70W (Load 500Ω) |
| Parameter | Value |
|---|---|
| Technical Parameters | HF-350D |
| Relative Humidity Range | ≤80 |
| Power | 220V±22v, 50Hz±1 |
| Operating Freq | 330-460kHz |
| Rated power | 1100 VA±10% |
| Type | CF |
| Power Consumption | ≤1100 VA (Cut function 400) |
| b) Relative Humidity | ≤95% |
| c) Atmospheric Pressure | 500hpa-1060 hpa |
| Power output | 400W |
| Six output mode | 1. Cut; 2. Blend 1; 3. Blend 2; 4. Electro Coag 1; 5. Electro Coag 2; 6. Bipolar Coagulation. |
| Output Rating | |
| a) Cut | 1W-400W (Load 800Ω) |
| b) Blend 1 | 1W-200W (Load 800Ω) |
| c) Blend 2 | 1W-150W (Load 800Ω) |
| d) Electro Coag 1 | 1W-120W (Load 800Ω) |
| e) Electro Coag 2 | 1W-100W (Load 800Ω) |
| Parameter | Value |
|---|---|
| Technical Parameters | HF-350C Argon Knife |
| Relative Humidity Range | ≤80 |
| Power | 220V±22v, 50Hz±1 |
| Operating Freq | 330-460kHz |
| Rated power | 1100 VA±10% |
| Type | CF |
| Power Consumption | ≤1100 VA (Cut function 400) |
| b) Relative Humidity | ≤95% |
| c) Atmospheric Pressure | 500hpa-1060 hpa |
| Parameter | Value |
|---|---|
| Technical Parameters | HFCM-350C |
| Relative Humidity Range | ≤80 |
| Power | 220V±22v, 50Hz±1 |
| Operating Freq | 330-460kHz |
| Rated power | 1100 VA±10% |
| Type | CF |
| Power Consumption | ≤1100 VA (Cut function 400) |
| b) Relative Humidity | ≤95% |
| c) Atmospheric Pressure | 500hpa-1060 hpa |
| Parameter | Value |
|---|---|
| Power Source | Electric |
| Material | Foam |
| Color | White |
| Type | Vertical |
| Size | 90mmX75mm |
Electrosurgical Equipment in the Operating Room
In operating-room planning the generator sits on a mobile cart or a fixed shelf beside the surgical table, with the electrode cable routed clear of the sterile field. Outlet positions and cable length are settled at the layout stage, before equipment is ordered.
Electrosurgical units are ordered with surgical tables, medical pendants and other theatre equipment; the operating room equipment list guide shows how such items are grouped for a project.
Electrosurgery Generator Output Modes
An electrosurgery generator is the main unit that supplies the output modes used during a procedure; electrodes, cables and controls connect to it. What a generator offers differs from model to model, so the specification table of the model under consideration is the reference for its modes.
Read the output modes of each model on its own. Where a table sets out cut, blend and coagulation outputs, those settings belong to that model and are not a range standard. Configuration questions about a planned generator are answered when you request a quotation for your project.
Electrosurgical Unit Terminology
ESU is the common abbreviation for electrosurgical unit and appears in purchase requests, tender schedules and equipment sheets next to the full name. It also appears in lower case, as esu, in running tender text. The abbreviation is a terminology note only; it carries no fixed specification, and output modes and configuration are shown in each model’s own specification table.
Buyers also write electro surgical unit, with a space, and electrical surgical unit. Both spellings describe the same equipment category as electrosurgical unit, so they lead to the same models on this page. Each model’s table remains the reference for its own modes and configuration.
Monopolar and Bipolar Modes
Monopolar output is an output mode or configuration for a model whose own specification table states it. Not every model on this page offers monopolar output, and a value taken from a model that offers the mode should not be applied to another model. Where a table is silent on the mode, keep the question open and request a quotation for your project.
Bipolar output follows the same rule and is confirmed per model. The Bipolar Electrosurgical Unit carries a high definition large LED indication, a feature of that model. Where a project needs monopolar and bipolar output together, note the required modes with the model and request a quotation for your project.
Electrosurgical Unit Sourcing
Distributors quoting an electrosurgical unit machine work from the model, not from the category name. The phrase is a plain description of the equipment; the substance sits in the specification table of each model and in the quantity and destination of the project. Confirm these points before quoting:
- the model and the output modes its table sets out
- the configuration quoted for that model
- quantity per model, with destination port or site
- the Incoterm that suits the shipment
Average lead time is within 15 working days in peak and off seasons, with actual timing confirmed per quotation. Payment terms include L/C, T/T, PayPal, Western Union and MoneyGram.
Quotation Steps for Electrosurgical Unit Projects
Huifeng Medical has exported since 2008 and sells to more than 50 countries across North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, the Middle East, Eastern Asia and Western Europe. More than 90% of production is exported.
- Send the equipment list and quantities for the project.
- Receive a quotation with model, configuration and terms.
- Confirm production scheduling.
- Inspection and packing before shipment.
- Shipping under the agreed Incoterm.
OEM and ODM work is available alongside the HFMED and SHANGYI brands, with terms confirmed per quotation; the OEM and ODM page sets out how that runs for a project.
How an order runs
- Send your requirements
- The equipment you need, the model or configuration, the quantity and the project or destination.
- Quotation
- Huifeng Medical replies with a quotation that confirms the model, configuration, MOQ, lead time and terms.
- MOQ and lead time
- For many listed models the minimum order quantity starts from 1 piece; the average lead time is within 15 working days. The MOQ, selling unit and timing for each order are confirmed in the quotation.
- Payment and Incoterms
- L/C, T/T, PayPal, Western Union and MoneyGram are accepted, with Incoterms such as FOB, CFR, CIF, DAP, DDP, FCA and EXW, confirmed per quotation.
- Production and shipping
- After confirmation the equipment is produced, inspected and packed for export, then shipped on the agreed terms.
Request a quotation
Send the model or configuration you need, the quantity and your project or destination.
Or write to sales@surgicallightmanufacturer.com