Surgical Lights Range and Project Scope

The models in this group are Operating Room Ceiling Lights, Shadowless Operating Lamp, Ceiling Mount Surgical Light, Hospital Surgical Lamp, Hospital Surgical Light and LED Surgery Light. Illuminance, light field, head configuration and mounting details are given in each model’s own specification table and are not range-wide values.

For units that move between rooms, see mobile surgical lights; for examination lighting, see examination lights.

Surgical light models and specifications

Operating Room Ceiling Lights
ParameterValue
Technical Parameters700mm head
Illuminance (Lux)≥160,000 lux
Color temperature3800±500K, 4400±500K, 5000±500K
Ultraviolet light irradiance within 40nm wave0.3W/M2
50% Spot Diameter (D50)55%
10%Spot Diameter (D10)291 mm
Depth Of Illuminance1400 mm
The adjusting range of Illumination %25~100%
Light Focus adjustment SystemManual
Terperature at surgeon’s head≤ 1°C
CRI RA95
Total Power Consumption80W
Batteryoptional
Size of light field250-300mm
Power supply voltageAC110-240V 50/60Hz
Total LED bulb quantity108pcs
Shadowless Operating Lamp
ParameterValue
Technical Parameters700mm head / 700mm head
Illuminance (Lux)≥160,000 lux / ≥160,000 lux at 1 meter distance.
Color temperature3800±500K, 4400±500K, 5000±500K
Ultraviolet light irradiance within 40nm wave0.3W/M2
50% Spot Diameter (D50)55%
10%Spot Diameter (D10)291 mm
Depth Of Illuminance1400 mm
The adjusting range of Illumination %25~100%
Light Focus adjustment SystemManual
Terperature at surgeon’s head≤ 1°C
CRI RA96
Total Power Consumption80W 80W
Batteryoptional
Size of light field250-300mm
Power supply voltageAC110-240V 50/60Hz
Total LED bulb quantity216 pcs
Surgery Light 4k
ParameterValue
Illuminance (Lux)≥160,000 lux / ≥140,000 lux
Color temperature3800±500K, 4400±500K, 5000±500K
Ultraviolet light irradiance within40nm wave0.3W/M2, 0.4W/M2
50% Spot Diameter (D50)55% / 51%
10% Spot Diameter (D10)291mm / 268mm
Depth Of Illuminance1400 mm
The adjusting range of Illumination %25~100%
Light Focus adjustment SystemManual
Terperature at surgeon’s head≤ 1°C
CRI RA96
Total Power Consumption80W/60W
Batteryoptional
Size of light field250-300mm
Power supply voltageAC110-240V 50/60Hz
Total LED bulb quantity180pcs
lmage device1/2.3 inch Exmor R CMOS
Effective pixelsabout 8.93 million pixels
Optical zoom20 times
Lens3.9 mm (f= wide)~46.8 mm (tele),F 1.8~F2.0
Signal system4K 2160 P/29.97,21609/25 FHDHD 1080 P/59094,
1080 P/150,1080i/59.94,1080i/50,720 P/59.94,720P/50
Lowest illuminance High sensitivity mode Color0.75 Ix(F1.8,AGC on,1/30 s)
Normal mode Color3 lx(F1.8,AGC on,1/30 s)
Shutter speed1/1 second to 1/10,000 second, 22 steps
Focus systemautomatic(sensitivity:normal, low), one-button
auto focus,manual,interval auto focus, zoom
trigger auto focus, focus compensation when
ICR mode is turned on
Ceiling Mount Surgical Light
ParameterValue
Illuminance≥145,000 Lux; <145,000 Lux
Colour temperature3800 K+300K; 4400 K+300K; 5000 K+300K
Spot diameter160-200mm
Input Power90VA
LED secondarylight-emitting tube power3.2V/3W
Number of LED secondarylight-emitting tubes120
ENDO≥10000 Lux
GL≥12000 Lux
Color rendering index (Ra)96≤Ra≤100
Total irradiance≤500W/m 2
Illumination depth20%: Notless than 1070 mm
60%: Notless than 560mm
Optional camera on the handle of lamp head and monitor on the third arm
Lowest height of installation3100 mm
ModelFCB-CV7100
Effective Pixels Approx. 2.38 Mega Pixels
Lens Value
optical zoom10x
Dig ital Zoom12x (120x with optical zoom)
Lens Focusf=3.8mm (wide) to 38mm (tele)
F valueF1.8 to F3.4
Monitor1080 P, 27 inch
Surgical Light Video Camera Market
ParameterValue
Illuminance≥145,000 Lux; ≥145,000 Lux; <160,000 Lux
Colour temperature3800 K+300K; 4400 K+300K; 5000 K+300K
Spot diameter160-200mm
Input Power90VA
LED secondarylight-emitting tube power3.2V/3W
Number of LED secondarylight-emitting tubes60+84+60 pcs
ENDO≥10000 Lux
GL≥12000 Lux
Color rendering index (Ra)96≤Ra≤100
Total irradiance≤500W/m2
Illumination depth20%: Notless than 1070 mm
60%: Notless than 560mm
Optional camera on the handle of lamp head and monitor on the third arm
Lowest height of installation3100 mm
ModelFCB-CV7100
Effective Pixels Approx. 2.38 Mega Pixels
Lens Value
optical zoom10x
Digital Zoom12x (120x with optical zoom)
Lens Focusf=3.8mm (wide) to 38mm (tele)
F valueF1.8 to F3.4
Monitor1080 P, 27 inch
Hospital Surgical Lamp
ParameterValue
Illuminance≥160,000 Lux; <160,000 Lux
Colour temperature3800 K+300K; 4400 K+300K; 5000 K+300K
Spot diameter160-200mm
Input Power90VA
LED secondarylight-emitting tube power3.2V/3W
Number of LED secondarylight-emitting tubes120
ENDO≥10000 Lux
GL≥12000 Lux
Color rendering index (Ra)96≤Ra≤100
Total irradiance≤500W/m 2
Illumination depth20%: Notless than 1070 mm
60%: Notless than 560mm
Optional camera on the handle of lamp head and monitor on the third arm
Lowest height of installation3100 mm
ModelFCB-CV7100
Effective Pixels Approx. 2.38 Mega Pixels
Lens Value
optical zoom10x
Dig ital Zoom12x (120x with optical zoom)
Lens Focusf=3.8mm (wide) to 38mm (tele)
F valueF1.8 to F3.4
Monitor1080 P, 27 inch
Hospital Surgical Light
ParameterValue
Illuminance≥145,000 Lux; <160,000 Lux
Colour temperature3800 K+300K; 4400 K+300K; 5000 K+300K
Spot diameter160-200mm
Input Power90VA
LED secondarylight-emitting tube power3.2V/3W
Number of LED secondarylight-emitting tubes120
ENDO≥10000 Lux
GL≥12000 Lux
Color rendering index (Ra)96≤Ra≤100
Total irradiance≤500W/m 2
Illumination depth20%: Notless than 1070 mm
60%: Notless than 560mm
Optional camera on the handle of lamp head and monitor on the third arm
Lowest height of installation3100 mm
ModelFCB-CV7100
Effective Pixels Approx. 2.38 Mega Pixels
Lens Value
optical zoom10x
Dig ital Zoom12x (120x with optical zoom)
Lens Focusf=3.8mm (wide) to 38mm (tele)
F valueF1.8 to F3.4
Monitor1080 P, 27 inch
LED Surgery Light
ParameterValue
Technical Parameters500mm head
Illuminance (Lux)≥140,000 lux
Color temperature3800±500K, 4400±500K, 5000±500K
Ultraviolet light irradiance within 40nm wave0.4W/M2
50% Spot Diameter (D50)51%
10%Spot Diameter (D10)268 mm
Depth Of Illuminance≥1400 mm
The adjusting range of Illumination %25~100%
Light Focus adjustment SystemManual
Terperature at surgeon’s head≤ 1°C
CRI RA95
Total Power Consumption60W
Batteryoptional
Size of light field250-300mm
Power supply voltageAC110-240V 50/60Hz
Total LED bulb quantity72pcs(12*6)
Emergency Time7 hours
Brightness adjustmentAutomatic 8-stage continuouslight adjustment
ENDOYES

Ceiling-Mounted Surgical Lights for Operating Rooms

The lights in this group are ceiling-mounted lamp heads carried on suspension arms above the surgical field.

Surgical tables are drawn into the same plan so the heads do not compete with other ceiling equipment for space.

Choosing Surgery Lights for a Project

Selection for surgery lights starts with the room rather than with the model name. Four factors usually decide the choice: the area the head has to cover around the incision, how the head is positioned and adjusted during a procedure, whether the room needs a single head or a double head, and how brightness and position are controlled at the table.

What a Ceiling-Mounted Surgical Light Consists Of

A ceiling-mounted surgical light consists of a lamp head that holds the LED light source and the optics shaping the beam, a suspension arm system that carries the head over the operating table and lets it be moved and locked, and a control interface for positioning and brightness.

Housing material, arm construction and control type differ between models, so the table attached to each model is the place to check construction. On the Shadowless Operating Lamp the lamp cap shell is made of aluminum alloy with good heat dissipation performance.

Operating Room Lights: Ceiling-Mounted Units

This page covers ceiling-mounted operating room lights only: heads fixed above the table. Mobile surgical lights are covered on mobile surgical lights, and examination lights on examination lights, where the fixture and the way it is supported are different.

As general practice, a ceiling-mounted unit stays in one room and is set over the table for the whole procedure, while a mobile unit is wheeled between rooms and used where no ceiling fixing is available. Where the mounting is still open, send the room details through the inquiry form and the arrangement is confirmed in the quotation.

Operating Room Lamp Terminology

Operating room lamp, operating lamp and surgical light are used for the same ceiling-mounted fixture, and this page uses the terms interchangeably. A buyer may meet all three names in a room schedule, a tender document or a quotation request, and they describe the same equipment.

No parameter from one model is carried to another, and each table stands on its own.

Planning Operating Room Surgical Lights into a Project

On a new build or a renovation, operating room surgical lights are planned room by room: the head configuration is decided for each room, the ceiling mounting and the routes for services are coordinated with the contractor, and delivery is sequenced against the fit-out so the heads arrive when the ceiling is ready.

Huifeng Medical was established in 1992, runs 3 factories each focused on a different product line, and exports more than 90% of its production to more than 50 countries.

LED Surgical Lights and Light Source

The LED surgical lights on this page are ceiling-mounted units built around an LED light source. Each model’s own table gives illuminance, light field size, adjustability and control method, and these differ from model to model, so there is no range-wide figure for the group.

Compare the tables against the room in question: depth of illumination and size of light field matter where the surgical field is deep or wide, and the way brightness is adjusted matters for how the team works at the table. Send the room or project for a quotation on the models you are comparing.

How an order runs

Send your requirements
The equipment you need, the model or configuration, the quantity and the project or destination.
Quotation
Huifeng Medical replies with a quotation that confirms the model, configuration, MOQ, lead time and terms.
MOQ and lead time
For many listed models the minimum order quantity starts from 1 piece; the average lead time is within 15 working days. The MOQ, selling unit and timing for each order are confirmed in the quotation.
Payment and Incoterms
L/C, T/T, PayPal, Western Union and MoneyGram are accepted, with Incoterms such as FOB, CFR, CIF, DAP, DDP, FCA and EXW, confirmed per quotation.
Production and shipping
After confirmation the equipment is produced, inspected and packed for export, then shipped on the agreed terms.

Request a quotation

Send the model or configuration you need, the quantity and your project or destination.

Or write to sales@surgicallightmanufacturer.com

* Required