Huifeng MedicalRequest a quoteQuote

Patient Monitor Catalog for Hospitals, Distributors and Contractors

Huifeng Medical presents a patient monitor catalog for hospitals, distributors and contractors.

Request a quote for this equipment

Established
1992
Production lines
More than 10
Sales
More than 50 countries
Green-framed monitor displaying multiple vital signs

Medical Monitoring and Patient Monitoring Systems

A patient monitoring system usually combines bedside monitor units, the sensors and cables used with them, and a planned position for each unit relative to the bed. Hospitals plan this equipment around department workflow, bed layout and the parameters clinicians expect to review.

For department planning, contractors and distributors can coordinate monitor positions with ICU beds and medical pendants. Each model’s own table gives its parameter set, and the models on this page should be compared model by model. Configuration, options and quantities are confirmed per quotation through the inquiry form. This is general ward-planning practice.

Patient monitor models and specifications

Dog Blood Pressure Monitor
ParameterValue
SpO 2 /NIBPBF
Application rangeCat/Dog/Horse/Medicine/Surgery/Operating Room
Display
Resolution800*600
One alarm indicator
One working indicator
One battery charge state indicator
Humidity15%-80%
Pressure86.0kPa-106.0kPa
Pressure86.0 kPa-106.0kPa
Power requirements
AC100~240V,50Hz/60Hz
DCBuilt-in rechargeable battery
Battery11.1V 24wh Li-ion battery
2h operating after full charge
5min operating after low battery alarm
Trend diagram/table720h
NIBP review1000 group
Wave review12h
Alarm revie200 alarm events
NIBP
MethodPulse wave oscillometry
Work modeManual/ Auto/ STAT
Measure interval of auto mode1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
Measuring Time of STAT Mode5 minutes
PR range40 ~ 240bpm
Measure & alarm rangeSYS 40 ~ 270mmHg DIA 10 ~ 215mmHg MEAN 20 ~ 235mmHg
SpO2
Measurement range0-100%
Resolution accuracy70%~100% ±2% 40%~69% ±3%
Measure/alarm range20- 300bpm
Resolution1bpm
Accuracy±3bpm
TEMP(optional)
Channel 1
Measure & alarm range0 ~ 50
Resolution0.1
Accuracy (no sensor)±0.1
Veterinary Multi-Parameter Monitor
ParameterValue
Patient rangeHorse, cattle, dog, cat, etc
Environment Requirement
Humidity15-95% non-condensing
Power supply
External Power supply
100-240V AC,50/60 HZ
Internal Battery Power Supply
TypeRechargeable li-ion,12v/4AHMax.24H charging,4H working
Trend
parameters graphic and tabular trends5s/piece, 8 hours,1min/piece,168 hours (24hourx7days)5min/piece, 1000 hours,
ECG
Lead mode5 -lead(R,L,F,N,C)
Lead selectionL,ll,ll,avR,avL,avF,V
Waveform3 and 7 channel selectable
Gain selection0.5mm/mv,1mm/mv,2mm/mv
Sweep speed12.5mm/s;25mm/s;50mm/s
Heart rate range15~350bpm
Accuracy+1bpm or +1%,whichecer is greater
Resolution1bpm
Filtersurgery mode:1~20Hz
monitor model0.5~40Hz
Diagnostic mode0.05~130Hz
Scaling signal1mv,+3%
Alarm range15~350bpm
S-T segment detecton
Measurement range2.0mV~+2.0mV
Alarm Range-2.0mV~+2.0mV
Accuracy-0.8mV~+0.8MV
Error+0.02Mv
Arrhythmia analysisYES
Multi-parameter Veterinary Monitor
ParameterValue
Patient rangeHorse, cattle, dog, cat, etc
Humidity15-95% non-condensing
Power supply
External Power supply
100-240V AC,50/60 HZ
Internal Battery Power Supply
TypeRechargeable li-ion,12v/4AHMax.24H charging,4H working
Trend
parameters graphic and tabular trends5s/piece, 8 hours,1min/piece,168 hours (24hourx7days),5min/piece, 1000 hours
NIBP
MethodDigital Automatic oscillometric
Operation modeManual/Automatic/continuous
Auto measurement timeAdjustable(1~480min)
Measurement UnitmmHg/Kpa selectable
Measurement typesSystolic,Diastolic, Mean
Measurement tange
Range of Systolic pressure40~270mmHg
Range of mean pressure20~235mmHg
Range of diastolic pressure10~215mmHg
Over-pressure protection
Resolution1 mmHg
AlarmSystolic.Diastolic,Mean
TEMP
Compatible probeYSl or CYF
Refreshing timeabout 1
Average measuring time<10s
Animal Monitor
ParameterValue
SPO2
SPO2 Range0~100%
SPO2 Accuracy70~100%,±2% <70%,Undefined
PI Range0~20%
PVI Range0.001%
PR Range25-250bpm
PR Accuracy±2bpm or ±2%(whichone is greater)
ECG
ECG Range0.15~5.5mV
ECG Resolution2.36uV/LSB
HR Range15~300bpm(Large animal) 15~350bpm(Small animal)
RR Range0~120bpm
RR Accuracy15~120rpm : ±2rpm or ±2% <15rpm:Undefined
TEMP
Range0-50°C
Accuracy±0.1°C
Resolution0.1°C
NIBP
Pressure Accuracy±2mmHg or ±1% of reading (take the larger value)
Resolution1mmHg
SYS RangeLarge animal:40-270mmHg Medium animal:40-200mmHg Small animal:40-130mmHg
DIA RangeLarge animal:10-210mmHg Medium animal:10-162mmHg Small animal:10-90mmHg
Mean RangeLarge animal:20-230mmHg Medium animal:20-170mmHg Small animal:20-100mmHg
RESP
Range Accuracy0-120Rpm 15-120Rpm ±2Rpm or ±2% of the reading (which one is larger) Others,undefined
Resolution1Rpm
Vet Vital Signs Monitor
ParameterValue
Range0~100%
Resolution1%
Range0~150rpm
Accuracy±1rpm(0~70rpm)Undefined(within other ranges)
Resolution1rpm
PR
Range25~250bpm
Accuracy±3bpm
Resolution1bpm
TEMP
Range0-50°C
Accuracy±1°C
Resolution0.1
Capnography
METHOD CO2 MEASUREMENT RANGEInfrared radiation absorption technology 0 ~ 20 Vol%
ACCURACY0 ~ 12 %: ± (0.2 Vol% + 2% of reading), 12 ~ 20 % : ± (0.2 Vol% + 6% of reading)
MEASUREMENT ACCURACY DRIFTaccuracy requirements within 6 hours
RESOLUTION0.1 Vol%
APNEA ALARM DELAY TIME20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
ALARM RANGE: EtCO20 ~ 150mmHg, FiCO2: 0 ~ 150mmHg, awRR: 0 ~ 150rpm
Veterinary Multi Parameter Monitor
ParameterValue
TEMP/SpO 2 /NIBPBF
ECG/RespCF
Application rangeCat/Dog/Horse/Medicine/Surgery/Operating Room
Humidity≤85%
Altitude-500 ~ 4600 m
AC100 ~ 240V, 50Hz/60Hz
DCBuilt-in rechargeable battery
Battery4000 mA 11.1V lithium battery
2h operating after full charge(one piece)
5min operating after low battery alarm
Trend diagram/table7x24h
NIBP review400 events
Wave review100min
Alarm review100 alarm events
ST Segment Range-2.0mV ~ +2.0mV
Accuracy0.02mV
Optional accessoriesCO2 module IBP module Nellcor SpO2 Trolley Wall mount Printer
Drive Pulse Oximeter
ParameterValue
Technical ParametersHF-81
Measurement range70-99%
Accuracy70%~99%: ±2 digits
0%~69% no definition
Resolution1%
Low perfusion performancePI=0.4%, SpO2=70%, PR=30bpm: Fluke Index II, SpO2 + 3 digits
Measure range30~240bpm
Accuracy±1bpm or ±1%
Resolution1bpm
TypeOLED display
ParametersSpO2, PR, waveform, Pulse bar
Ambient Humidity≤80% no condensation in operation
≤93% no condensation in storage
Atmosphere pressure86kPa~106kPa
Dimension58mm*35mm*30mm
Weight (without battery)33g
Vet Monitor
ParameterValue
SP02Range:0~100% Resolution:1% Accuracy: plus or minus 4%
PRRange:30~240bpm Resolution: 1bpm Accuracy: plus or minus 3bpm
ETCO2Range:0~99mmHg Resolution:1mmHg
NIBP Dogsystolic pressure40~200 mmHg diastolic10~150 mmHg average20~165 mmHg
NIBP Catsystolic pressure40~135 mmHg diastolic10~95 mmHg average20~110 mmHg
Working humidity range≤85 % humidity
Storage≤93% (No condensation)
Altitude of working-500-4,600 m(-1,600-15,000 inch)
Altitude of torage-500-13,100 m(-1,600-43,000 inch)
Electrical specification 100 ~ 240 V ac, 50/60 Hz, maximum input power 70VA
FUSE T1.5A Battery capacity:2000 mAh
Size255*152*100mm

ICU Monitors

In critical care areas, an ICU monitor is used at the bedside to show the parameters selected for that bed. The parameter set depends on the individual model and is given in that model’s own specification table, not as a range-wide list. Buyers specifying critical care beds should compare each model’s table against the parameters their department expects to review.

ICU configuration, mounting and options are confirmed per quotation. Huifeng Medical offers OEM and ODM terms as well as the HFMED brand; those terms are confirmed per quotation.

For an ICU vital signs monitor, the displayed parameters depend on the model. Send the parameter set you need together with bed quantities so the quotation can address the correct model and configuration. Related planning pages include medical pendants and ICU beds.

Portable Patient Monitors

A portable patient monitor is preferred when the monitor must move with the patient between areas, or when a temporary or overflow bed space needs monitoring. Portability affects how a unit is carried, mounted and connected, so the bed layout and movement route should be planned before selection.

The buyer can send the bed layout and movement routes with the inquiry so the quotation can address the correct model.

Veterinary Monitoring Equipment

Shanghai Fangzheng Medical Equipments Co., Ltd., a veterinary equipment company, is a subsidiary of Huifeng Medical.

Parameters for each veterinary model are given only where that model’s own specification table provides them. Each table should be read on its own terms. For surgical work alongside monitoring, the veterinary operating tables page shows related equipment.

Patient Monitor Machine Procurement and Quotation

Before ordering a patient monitor machine for a project or distribution orders, settle the model, parameter set, accessories and packing with the quotation. Huifeng Medical’s average lead time is within 15 working days in both peak and off seasons; actual timing is confirmed per quotation.

  • Payment terms: L/C, T/T, PayPal, Western Union and MoneyGram, confirmed per quotation.
  • Incoterms: FOB, CFR, CIF, DAP, DDP, FCA and EXW, confirmed per quotation.
  • OEM and ODM terms and HFMED brand supply are confirmed per quotation.
  • Send the equipment list and quantities through the inquiry form for a quotation.

The normal service path is to send the equipment list and quantities, receive a quotation, proceed to production, then inspection and packing, then shipping. Huifeng Medical was established in 1992 and runs 3 factories, each focused on a different product line. Use the contact page for a quotation.

How an order runs

Send your requirements
The equipment you need, the model or configuration, the quantity and the project or destination.
Quotation
Huifeng Medical replies with a quotation that confirms the model, configuration, MOQ, lead time and terms.
MOQ and lead time
For many listed models the minimum order quantity starts from 1 piece; the average lead time is within 15 working days. The MOQ, selling unit and timing for each order are confirmed in the quotation.
Payment and Incoterms
L/C, T/T, PayPal, Western Union and MoneyGram are accepted, with Incoterms such as FOB, CFR, CIF, DAP, DDP, FCA and EXW, confirmed per quotation.
Production and shipping
After confirmation the equipment is produced, inspected and packed for export, then shipped on the agreed terms.

Request a quotation

Send the model or configuration you need, the quantity and your project or destination.

Or write to sales@surgicallightmanufacturer.com

* Required