Patient Monitor Catalog for Hospitals, Distributors and Contractors
Huifeng Medical presents a patient monitor catalog for hospitals, distributors and contractors.
Request a quote for this equipment
- Established
- 1992
- Production lines
- More than 10
- Sales
- More than 50 countries

Medical Monitoring and Patient Monitoring Systems
A patient monitoring system usually combines bedside monitor units, the sensors and cables used with them, and a planned position for each unit relative to the bed. Hospitals plan this equipment around department workflow, bed layout and the parameters clinicians expect to review.
For department planning, contractors and distributors can coordinate monitor positions with ICU beds and medical pendants. Each model’s own table gives its parameter set, and the models on this page should be compared model by model. Configuration, options and quantities are confirmed per quotation through the inquiry form. This is general ward-planning practice.

Upright monitor displaying blood pressure and waveforms 
Compact horizontal monitor with waveforms and controls
Patient monitor models and specifications
| Parameter | Value |
|---|---|
| SpO 2 /NIBP | BF |
| Application range | Cat/Dog/Horse/Medicine/Surgery/Operating Room |
| Display | |
| Resolution | 800*600 |
| One alarm indicator | |
| One working indicator | |
| One battery charge state indicator | |
| Humidity | 15%-80% |
| Pressure | 86.0kPa-106.0kPa |
| Pressure | 86.0 kPa-106.0kPa |
| Power requirements | |
| AC | 100~240V,50Hz/60Hz |
| DC | Built-in rechargeable battery |
| Battery | 11.1V 24wh Li-ion battery |
| 2h operating after full charge | |
| 5min operating after low battery alarm | |
| Trend diagram/table | 720h |
| NIBP review | 1000 group |
| Wave review | 12h |
| Alarm revie | 200 alarm events |
| NIBP | |
| Method | Pulse wave oscillometry |
| Work mode | Manual/ Auto/ STAT |
| Measure interval of auto mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s) |
| Measuring Time of STAT Mode | 5 minutes |
| PR range | 40 ~ 240bpm |
| Measure & alarm range | SYS 40 ~ 270mmHg DIA 10 ~ 215mmHg MEAN 20 ~ 235mmHg |
| SpO2 | |
| Measurement range | 0-100% |
| Resolution accuracy | 70%~100% ±2% 40%~69% ±3% |
| Measure/alarm range | 20- 300bpm |
| Resolution | 1bpm |
| Accuracy | ±3bpm |
| TEMP(optional) | |
| Channel 1 | |
| Measure & alarm range | 0 ~ 50 |
| Resolution | 0.1 |
| Accuracy (no sensor) | ±0.1 |
| Parameter | Value |
|---|---|
| Patient range | Horse, cattle, dog, cat, etc |
| Environment Requirement | |
| Humidity | 15-95% non-condensing |
| Power supply | |
| External Power supply | |
| 100-240V AC,50/60 HZ | |
| Internal Battery Power Supply | |
| Type | Rechargeable li-ion,12v/4AHMax.24H charging,4H working |
| Trend | |
| parameters graphic and tabular trends | 5s/piece, 8 hours,1min/piece,168 hours (24hourx7days)5min/piece, 1000 hours, |
| ECG | |
| Lead mode | 5 -lead(R,L,F,N,C) |
| Lead selection | L,ll,ll,avR,avL,avF,V |
| Waveform | 3 and 7 channel selectable |
| Gain selection | 0.5mm/mv,1mm/mv,2mm/mv |
| Sweep speed | 12.5mm/s;25mm/s;50mm/s |
| Heart rate range | 15~350bpm |
| Accuracy | +1bpm or +1%,whichecer is greater |
| Resolution | 1bpm |
| Filter | surgery mode:1~20Hz |
| monitor model | 0.5~40Hz |
| Diagnostic mode | 0.05~130Hz |
| Scaling signal | 1mv,+3% |
| Alarm range | 15~350bpm |
| S-T segment detecton | |
| Measurement range | 2.0mV~+2.0mV |
| Alarm Range | -2.0mV~+2.0mV |
| Accuracy | -0.8mV~+0.8MV |
| Error | +0.02Mv |
| Arrhythmia analysis | YES |
| Parameter | Value |
|---|---|
| Patient range | Horse, cattle, dog, cat, etc |
| Humidity | 15-95% non-condensing |
| Power supply | |
| External Power supply | |
| 100-240V AC,50/60 HZ | |
| Internal Battery Power Supply | |
| Type | Rechargeable li-ion,12v/4AHMax.24H charging,4H working |
| Trend | |
| parameters graphic and tabular trends | 5s/piece, 8 hours,1min/piece,168 hours (24hourx7days),5min/piece, 1000 hours |
| NIBP | |
| Method | Digital Automatic oscillometric |
| Operation mode | Manual/Automatic/continuous |
| Auto measurement time | Adjustable(1~480min) |
| Measurement Unit | mmHg/Kpa selectable |
| Measurement types | Systolic,Diastolic, Mean |
| Measurement tange | |
| Range of Systolic pressure | 40~270mmHg |
| Range of mean pressure | 20~235mmHg |
| Range of diastolic pressure | 10~215mmHg |
| Over-pressure protection | |
| Resolution | 1 mmHg |
| Alarm | Systolic.Diastolic,Mean |
| TEMP | |
| Compatible probe | YSl or CYF |
| Refreshing time | about 1 |
| Average measuring time | <10s |
| Parameter | Value |
|---|---|
| SPO2 | |
| SPO2 Range | 0~100% |
| SPO2 Accuracy | 70~100%,±2% <70%,Undefined |
| PI Range | 0~20% |
| PVI Range | 0.001% |
| PR Range | 25-250bpm |
| PR Accuracy | ±2bpm or ±2%(whichone is greater) |
| ECG | |
| ECG Range | 0.15~5.5mV |
| ECG Resolution | 2.36uV/LSB |
| HR Range | 15~300bpm(Large animal) 15~350bpm(Small animal) |
| RR Range | 0~120bpm |
| RR Accuracy | 15~120rpm : ±2rpm or ±2% <15rpm:Undefined |
| TEMP | |
| Range | 0-50°C |
| Accuracy | ±0.1°C |
| Resolution | 0.1°C |
| NIBP | |
| Pressure Accuracy | ±2mmHg or ±1% of reading (take the larger value) |
| Resolution | 1mmHg |
| SYS Range | Large animal:40-270mmHg Medium animal:40-200mmHg Small animal:40-130mmHg |
| DIA Range | Large animal:10-210mmHg Medium animal:10-162mmHg Small animal:10-90mmHg |
| Mean Range | Large animal:20-230mmHg Medium animal:20-170mmHg Small animal:20-100mmHg |
| RESP | |
| Range Accuracy | 0-120Rpm 15-120Rpm ±2Rpm or ±2% of the reading (which one is larger) Others,undefined |
| Resolution | 1Rpm |
| Parameter | Value |
|---|---|
| Range | 0~100% |
| Resolution | 1% |
| Range | 0~150rpm |
| Accuracy | ±1rpm(0~70rpm)Undefined(within other ranges) |
| Resolution | 1rpm |
| PR | |
| Range | 25~250bpm |
| Accuracy | ±3bpm |
| Resolution | 1bpm |
| TEMP | |
| Range | 0-50°C |
| Accuracy | ±1°C |
| Resolution | 0.1 |
| Capnography | |
| METHOD CO2 MEASUREMENT RANGE | Infrared radiation absorption technology 0 ~ 20 Vol% |
| ACCURACY | 0 ~ 12 %: ± (0.2 Vol% + 2% of reading), 12 ~ 20 % : ± (0.2 Vol% + 6% of reading) |
| MEASUREMENT ACCURACY DRIFT | accuracy requirements within 6 hours |
| RESOLUTION | 0.1 Vol% |
| APNEA ALARM DELAY TIME | 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s |
| ALARM RANGE: EtCO2 | 0 ~ 150mmHg, FiCO2: 0 ~ 150mmHg, awRR: 0 ~ 150rpm |
| Parameter | Value |
|---|---|
| TEMP/SpO 2 /NIBP | BF |
| ECG/Resp | CF |
| Application range | Cat/Dog/Horse/Medicine/Surgery/Operating Room |
| Humidity | ≤85% |
| Altitude | -500 ~ 4600 m |
| AC | 100 ~ 240V, 50Hz/60Hz |
| DC | Built-in rechargeable battery |
| Battery | 4000 mA 11.1V lithium battery |
| 2h operating after full charge(one piece) | |
| 5min operating after low battery alarm | |
| Trend diagram/table | 7x24h |
| NIBP review | 400 events |
| Wave review | 100min |
| Alarm review | 100 alarm events |
| ST Segment Range | -2.0mV ~ +2.0mV |
| Accuracy | 0.02mV |
| Optional accessories | CO2 module IBP module Nellcor SpO2 Trolley Wall mount Printer |
| Parameter | Value |
|---|---|
| Technical Parameters | HF-81 |
| Measurement range | 70-99% |
| Accuracy | 70%~99%: ±2 digits |
| 0%~69% no definition | |
| Resolution | 1% |
| Low perfusion performance | PI=0.4%, SpO2=70%, PR=30bpm: Fluke Index II, SpO2 + 3 digits |
| Measure range | 30~240bpm |
| Accuracy | ±1bpm or ±1% |
| Resolution | 1bpm |
| Type | OLED display |
| Parameters | SpO2, PR, waveform, Pulse bar |
| Ambient Humidity | ≤80% no condensation in operation |
| ≤93% no condensation in storage | |
| Atmosphere pressure | 86kPa~106kPa |
| Dimension | 58mm*35mm*30mm |
| Weight (without battery) | 33g |
| Parameter | Value |
|---|---|
| SP02 | Range:0~100% Resolution:1% Accuracy: plus or minus 4% |
| PR | Range:30~240bpm Resolution: 1bpm Accuracy: plus or minus 3bpm |
| ETCO2 | Range:0~99mmHg Resolution:1mmHg |
| NIBP Dog | systolic pressure40~200 mmHg diastolic10~150 mmHg average20~165 mmHg |
| NIBP Cat | systolic pressure40~135 mmHg diastolic10~95 mmHg average20~110 mmHg |
| Working humidity range | ≤85 % humidity |
| Storage | ≤93% (No condensation) |
| Altitude of working | -500-4,600 m(-1,600-15,000 inch) |
| Altitude of torage | -500-13,100 m(-1,600-43,000 inch) |
| Electrical specification 100 ~ 240 V ac, 50/60 Hz, maximum input power 70VA | |
| FUSE T1.5A Battery capacity:2000 mAh | |
| Size | 255*152*100mm |
ICU Monitors
In critical care areas, an ICU monitor is used at the bedside to show the parameters selected for that bed. The parameter set depends on the individual model and is given in that model’s own specification table, not as a range-wide list. Buyers specifying critical care beds should compare each model’s table against the parameters their department expects to review.
ICU configuration, mounting and options are confirmed per quotation. Huifeng Medical offers OEM and ODM terms as well as the HFMED brand; those terms are confirmed per quotation.
For an ICU vital signs monitor, the displayed parameters depend on the model. Send the parameter set you need together with bed quantities so the quotation can address the correct model and configuration. Related planning pages include medical pendants and ICU beds.
Portable Patient Monitors
A portable patient monitor is preferred when the monitor must move with the patient between areas, or when a temporary or overflow bed space needs monitoring. Portability affects how a unit is carried, mounted and connected, so the bed layout and movement route should be planned before selection.
The buyer can send the bed layout and movement routes with the inquiry so the quotation can address the correct model.
Veterinary Monitoring Equipment
Shanghai Fangzheng Medical Equipments Co., Ltd., a veterinary equipment company, is a subsidiary of Huifeng Medical.
Parameters for each veterinary model are given only where that model’s own specification table provides them. Each table should be read on its own terms. For surgical work alongside monitoring, the veterinary operating tables page shows related equipment.
Patient Monitor Machine Procurement and Quotation
Before ordering a patient monitor machine for a project or distribution orders, settle the model, parameter set, accessories and packing with the quotation. Huifeng Medical’s average lead time is within 15 working days in both peak and off seasons; actual timing is confirmed per quotation.
- Payment terms: L/C, T/T, PayPal, Western Union and MoneyGram, confirmed per quotation.
- Incoterms: FOB, CFR, CIF, DAP, DDP, FCA and EXW, confirmed per quotation.
- OEM and ODM terms and HFMED brand supply are confirmed per quotation.
- Send the equipment list and quantities through the inquiry form for a quotation.
The normal service path is to send the equipment list and quantities, receive a quotation, proceed to production, then inspection and packing, then shipping. Huifeng Medical was established in 1992 and runs 3 factories, each focused on a different product line. Use the contact page for a quotation.
How an order runs
- Send your requirements
- The equipment you need, the model or configuration, the quantity and the project or destination.
- Quotation
- Huifeng Medical replies with a quotation that confirms the model, configuration, MOQ, lead time and terms.
- MOQ and lead time
- For many listed models the minimum order quantity starts from 1 piece; the average lead time is within 15 working days. The MOQ, selling unit and timing for each order are confirmed in the quotation.
- Payment and Incoterms
- L/C, T/T, PayPal, Western Union and MoneyGram are accepted, with Incoterms such as FOB, CFR, CIF, DAP, DDP, FCA and EXW, confirmed per quotation.
- Production and shipping
- After confirmation the equipment is produced, inspected and packed for export, then shipped on the agreed terms.
Request a quotation
Send the model or configuration you need, the quantity and your project or destination.
Or write to sales@surgicallightmanufacturer.com